Consumer Unit Upgrade
Friern Barnet
Old fuse box, repeated tripping or not enough modern protection in Friern Barnet? We test the existing circuits first and tailor the board design to semis with deep ground floors and converted properties near N11, explaining any faults before replacement.
NICEIC Registered Electrician · 15+ Years Experience · Full BS 7671 Certification · 5-Star Rated on Google
Your Fuse Box Upgrade Worries Answered in Friern Barnet
Worried about mess, losing power, how the new unit will look or unexpected extras? Here is what we check and agree before installation.
Will replacing my fuse box make a mess in my home?
We protect the area around the existing fuse box and keep the work centred there wherever possible. If new cables, casing or access work is needed, we show you where it will go and agree it before starting, so you know what will be visible and what making-good is included.
Will I be left without power for days?
The electricity must be switched off while the old board is removed and the new one is connected and tested. We usually aim to complete the main replacement work and restore power within 3–4 hours. If testing finds a fault that prevents safe reconnection, we explain it before carrying out any additional work.
What will the new fuse box look like?
Before work starts, we explain the likely size and position of the new metal consumer unit. The circuits are clearly labelled, and if a larger enclosure, cupboard alteration or visible cable casing may be needed, we agree the appearance with you first.
What happens if testing finds an existing fault?
Pre-change testing can reveal a fault that the old fuse box did not show. If that happens, we explain the problem and its effect before carrying out extra work. The quotation keeps any additional repair separate and states the testing, certification and Building Control notification included where applicable.
A Friern Barnet Semi — 1980s Board on Borrowed Time, Pre-Sale Survey Due
Friern Barnet properties do not all present the same electrical layout. The survey separates Victorian & Edwardian Terraces from 1930s–1960s Semis & Council Properties before the work is specified.
That distinction guides access, circuit testing and the written consumer unit replacement scope without relying on unsupported assumptions about the address.
I replaced the board with a 14-way full-RCBO unit and retested every circuit — the new install reads under 5 mA leakage per circuit.
EIC issued. The sale survey came back clean two weeks later.
What Our Customers Say About Us
Real reviews from homeowners and landlords across Friern Barnet and the wider London Borough of Barnet. Live Google reviews below — for all reviews across platforms, see our testimonials page →
Our Fuse Box / Consumer Unit Installations
Installation examples from across North London — FuseBox & Wylex RCBO boards, fully certified.
Book Your Free Fuse Box / Consumer Unit Survey
Tell us about your Friern Barnet property and we’ll arrange a free no-obligation survey — fixed price quotation after the scope is confirmed.
NICEIC Registered
Consumer-unit replacements are designed, installed and tested to the current requirements of BS 7671, with the applicable electrical certificate and Building Regulations documentation.
Fixed Price Quote
Free site survey, written quotation after the survey — no hourly billing, no surprise extras. From £800 standard, £950 premium, £1,200 large boards.
Planned Installation
Many standard consumer-unit replacements can be completed in one planned visit. Circuit faults, access or remedial work can extend the timescale and isolation period.
From £800
Standard 5–7 way RCBO board from £800. Premium 8–12 way from £950. 16+ way large-property boards from £1,200. HMO compliance pack quoted bespoke.
Signs Your Friern Barnet Property Needs a New Fuse Box / Consumer Unit
Six tells we look for in Friern Barnet fuse-box surveys. If two or more apply, a board replacement is usually the right call — not a repair.
Tripping that won’t reset
If your RCD trips and resets briefly then drops again the same evening, that’s a fault on a circuit — not a fuse box that just “needs a swap”. We isolate it during the install so the new board doesn’t inherit the same fault.
Burning smell or scorch marks
Brown discolouration around the main switch or burning plastic smell from the meter cupboard means heat damage at the consumer unit. Stop using high-load appliances and call us — this is a same-day priority job.
Wirewound or rewireable fuses
Old porcelain fuse holders with rewireable wire, or cartridge fuses with no MCBs at all, mean the board is from before 1980 and has zero RCD protection. EICR will fail it on C2; insurers may refuse claims.
Failed EICR or insurer refusal
C1 or C2 codes for “no RCD on socket circuits”, “outdated consumer unit”, or “non-compliant with current standards” are all board-level fixes. Send us the EICR and we’ll quote remedial work without a survey.
HMO licensing inspection
AFDD requirements depend on the installation, the current requirements of BS 7671 and any property-specific HMO licence conditions. An HMO inspection may identify additional circuit protection required by the installation design or licence conditions. The board and protective devices must be selected for the individual property.
Frequent appliance damage
If your TV, fridge, or boiler PCB has died more than once in the last few years, that’s typically a Type 2 SPD problem — older boards have no surge protection. New install adds SPD as standard.
How We Replace Your Fuse Box / Consumer Unit
Professional install from start to finish. Many standard consumer-unit replacements can be completed in one planned visit; circuit condition, access and remedial work can extend the timescale.
Initial Assessment
We check your incoming supply, earthing arrangement (TT vs TN-C-S), circuit count, RCD/SPD status, EICR history if any, and confirm whether AFDDs are required (HMO sleeping rooms). The survey is free with no obligation and you get a written written quotation after the survey.
Isolation & Removal
DNO main fuse pulled with permission, existing tails isolated, old board removed cleanly. We cap and label every circuit before disconnecting so reconnection is methodical, not guesswork. No live working at any stage.
New Unit Installation
Modern consumer unit (FuseBox, Wylex, Hager or Schneider) fitted with new 25mm meter tails, 100A main switch, full RCBO protection per circuit, Type 2 SPD on the main bus, and AFDDs where required. Cables labelled and torque-checked.
Testing & Verification
Full BS 7671 testing: insulation resistance (every circuit), Zs / Ze loop impedance, RCD trip times, SPD verification, polarity checks, and earth fault path. Any pre-existing fault is logged and discussed before we re-energise.
Fault Finding (If Needed)
If a circuit fails testing on the new board (typically a hidden borrowed neutral or insulation breakdown on an existing run), we find and fix it the same day where possible. Most fixes add £80–£180; major issues are quoted before any extra work starts.
Certification & Handover
Electrical Installation Certificate issued, photographed install record, written labels inside the board, Building Control notification through our NICEIC registration, and a verbal walkthrough of the new RCBOs and SPD test buttons. 12-month workmanship guarantee starts on handover.
Fuse Box / Consumer Unit Replacement Pricing
Quick reference for Friern Barnet homeowners. Fixed quotes given after a free site survey.
- ✓ New RCBO / Dual RCD consumer unit
- ✓ 100A main switch & 25mm meter tails
- ✓ Type 2 SPD surge protection
- ✓ Full BS 7671 testing & certification
- ✓ 12-month workmanship guarantee
- ★ 8–12 way full RCBO board
- ★ Individual circuit protection
- ★ Type 2 SPD & 100A main switch
- ★ FuseBox / Wylex / Hager premium unit
- ★ Priority install scheduling
- ✓ 16+ way full RCBO board
- ✓ Individual circuit protection
- ✓ Type 2 SPD & 100A main switch
- ✓ Full circuit schedule documentation
- ✓ 12-month workmanship guarantee
Nearby North London areas we cover for fuse box / consumer unit replacement
Consumer Unit Upgrade Questions for Friern Barnet
Property-specific questions for Friern Barnet, followed by practical answers about consumer unit replacement.
Barnet consumer units coverage · North London consumer units
I'm planning a kitchen extension in Friern Barnet — should I upgrade the fuse box at the same time?
Cheaper together. A Friern Barnet N11 kitchen extension around Friern Barnet Lane adds 3-4 new circuits. Barnet Council Building Control notification under Part P. Most pre-2010 N11 boards lack spare ways or are dual-RCD topology that won't take the new circuits comfortably. Single-mobilisation saves about £500.
Friern Barnet semi with a converted garage office — does the supply need an upgrade first?
Usually yes for the supply. Friern Barnet semis typically have 80A supplies — fine for basic garage-office sockets, tight margin once a wall heater, dehumidifier, or AC is added. We check supply, diversity-calc the load, and apply for an uplift via UK Power Networks if needed.
Family of 5 in Friern Barnet, constantly tripping the kitchen circuit — can a new fuse box fix it?
Yes — typically topology, not fault. Friern Barnet boards mostly 1990s-2010s dual-RCD. Family-of-five kitchen demand on one RCD bank crosses 30 mA cumulative leakage. Full-RCBO board fixes permanently.
What's the difference between RCD and RCBO consumer units? Which one do I need?
Both protect against electric shock and electrical fire. The difference is granularity.
- RCD consumer unit (typically dual-RCD): Two big trip switches, each protecting a group of circuits. If one circuit faults, the whole RCD group trips — you lose the kitchen, lights, and sockets together.
- RCBO consumer unit (one RCBO per circuit): Each circuit has its own combined trip switch. If the kitchen socket faults, only that circuit goes off — the rest stay live.
Why we recommend RCBO for most Friern Barnet installs:
- Faster fault diagnosis — you know immediately which circuit is faulty
- Less disruption — one bad iron doesn't kill the whole upstairs lighting
- Better with modern electronics — RCBOs are more sensitive and reliable
When dual-RCD is fine: small flats with simple circuit layouts, properties on a tight budget, short-term landlord-let where cost beats convenience.
Cost difference: typically £150 between dual-RCD (£800) and full RCBO (£950). For most homeowners we recommend the RCBO upgrade — it pays for itself the first time a fault localises rather than killing half the house.
Do I really need a metal consumer unit, or is a plastic fuse box OK?
This is the most common scare we see in Friern Barnet — the fear-driven upsell to landlords.
Honest answer: plastic fuse boxes fitted before 1 January 2016 are still legal and don't automatically fail an EICR. They were the standard at the time of fitting. They become a problem only when:
- The plastic enclosure shows signs of overheating or burn marks (genuine C2)
- The board has no RCD protection on socket circuits (the fail reason isn't the plastic — it's the missing RCDs)
- The original installation was non-compliant when fitted
Since 1 January 2016, all new consumer units in domestic properties must be made of non-combustible material (typically metal). This is a forward-looking requirement — your existing plastic fuseboard doesn't get retrofitted just because the rules changed for new installs.
What you should worry about: not the colour of the box. Worry about RCD coverage, the age of the wiring, whether the existing fuse box has been properly maintained, and whether your EICR has C1/C2 codes against the consumer unit specifically. If an electrician quotes you for "a metal consumer unit because plastic fails EICR" without that nuance — get a second opinion.
Adding an other high-load equipment to my Friern Barnet driveway — will the existing fuse box take it?
Supply — Friern Barnet properties usually on 80A. CU — needs spare 32A way or it's part of the install. RCBO — Type B for cheaper chargers, Type A for higher-spec. Diversity calc with the future high-load equipment installer beforehand.
Will my old wiring still work with a new fuse box?
Almost always yes. The new consumer unit is the brain; your existing circuits are the nervous system. We connect to your existing circuit cables — they don't get rewired.
What we test before we commit:
- Insulation resistance on every circuit (must be at or above 1MΩ; healthy 1990s+ installs typically read above 200MΩ)
- Earth continuity — needed for RCD/RCBO to work safely
- Loop impedance — the circuit's ability to clear a fault
If a circuit fails any of these tests, we tell you before we commit. Options:
- Single circuit fix (£100-£300) — repair the fault and continue
- Targeted partial rewire of just that circuit (£300-£600)
- Hold the upgrade and discuss whether a partial or full rewire is now better value
Common Friern Barnet scenarios where wiring fails: 1950s-60s rubber-insulated cable in upstairs lighting circuits (Friern Barnet Lane and Friern Barnet Lane period properties), borrowed neutrals from DIY work, undersized cables on extension circuits.
We never "just power it back up" with a circuit that failed testing — that's how fires start. Honest tradeoffs only.
I've been quoted £800. What if extra issues come up during the install — does the price go up?
Honest answer: the £800 is fixed for the standard scope. Any extras are quoted upfront, never sprung on you mid-install.
What's covered in £800 (no surprise add-ons):
- The new consumer unit / fuse board (quality metal, 6-10 ways)
- RCD protection on socket and lighting circuits
- Re-terminating every existing circuit, properly labelled
- Full insulation, earth, and RCD testing on every circuit
- The Electrical Installation Certificate (EIC)
- Plaster patching with bonding plaster around the install
What CAN add to the price (we tell you before we start, with a fixed quote):
- Circuits failing insulation testing — we'll show you the readings, and you decide: targeted repair (£100-£300 per circuit) or hold the upgrade for a partial rewire conversation
- Incoming supply needs upgrading — rare; happens when adding heavy load like an other high-load equipment or heat pump. We tell you upfront if your supply is borderline
- You opt for the premium tier — £950 (RCBO every circuit + surge protection) or £1,200+ (larger split-load board)
What we never do: discover a "problem" mid-install and charge you for it without your sign-off first. If we find something during testing, work pauses until you've decided. No scope creep.
I'm planning to sell my Friern Barnet house — will the buyer's surveyor flag the fuse box?
Yes — surveyors flag pre-2010 boards in Homebuyer Reports. Friern Barnet solicitors usually ask for a recent EICR. Upgrading before listing nets £2-3k after the £800 spend.
Heat pump going in next year — does my Friern Barnet fuse box need replacing now or later?
Now is usually smarter. ASHPs need 25-32A dedicated circuit, Type 2 SPD, CU sized for load. Pre-2010 Friern Barnet board means the heat-pump installer adds the CU upgrade at a markup.
Will the new consumer unit be ready for an other high-load equipment, heat pump, or smart home?
Yes — and we set up Friern Barnet consumer units for it as standard. What we include:
- Spare 32A way on the fuseboard, labelled and ready for a 7kW or 22kW dedicated high-load circuit installation
- Adequate supply headroom — we check your incoming supply and tell you upfront if a heat pump or other high-load equipment needs a supply upgrade (often the headroom is fine, but worth confirming)
- SPD (surge protection) on the premium tier (£950) — protects every modern electronic in the house from voltage spikes
- Smart-home-ready circuits — neutrals to switch positions if you specify (most period houses don't have these, blocking smart switch installs later)
What gets retrofitted later costs more. Adding extra circuits to an existing fuse box later — chasing walls, lifting floor coverings, isolating the supply again — is more disruptive and costs more than specifying spare ways during the consumer unit upgrade itself, which is marginal cost only.
Tell us at the survey stage what you might add in the next 5 years — future high-load equipment, heat pump, hot tub, garden room, second other high-load equipment, home office. We size the board around your plans, not just your current circuits.
Will the consumer unit upgrade damage my walls or decoration?
Almost never. Unlike a rewire, a consumer unit replacement is contained to the meter cupboard — usually under the stairs, in a hallway recess, or in a kitchen cupboard. The work stays in that one spot.
What we do during the install:
- Disconnect existing circuits at the old fuse box, label every cable
- Remove the old fuseboard from its mounting point
- Mount the new consumer unit in the same position (same screw holes where possible)
- Re-terminate every circuit into the new board
- Test, certify, and label every circuit on the new unit's chart
What we don't do:
- Chase walls
- Lift floorboards (unless an existing cable is too short to reach the new connection point — rare)
- Disturb skirting, sockets, or switches anywhere else in the house
- Affect any decoration outside the meter cupboard
The only plaster work: if the new board is a different physical size than the old one, we may need to patch a small area of bonding plaster around the mounting position. That's included; finishing coats and any decoration are a decorator's job.
Friern Barnet properties with the original fuse box in a tight under-stairs space sometimes need a little extra work to fit a wider modern board — we'll show you the position before we start so you can decide whether to keep it where it is or relocate.
Need a Fuse Box / Consumer Unit Replacement in Friern Barnet?
Professional fuse box replacement and consumer unit installation across Friern Barnet N11 / N11 and surrounding areas of the London Borough of Barnet. Free site survey, fixed prices, fully certified the current edition of BS 7671.