EICR Testing & Inspection
Bounds Green
Need to know whether the electrics are safe and what genuinely requires attention in Bounds Green? We plan access around divided terraces & shared houses and cross-borough n11/n22 homes, explain every recorded observation and provide a clear EICR without hiding limitations.
Qualified Electrician · 15+ Years Experience · Full EICR Report Included · 5-Star Rated on Google
Your EICR Worries Answered in Bounds Green
Worried about mess, losing power, an unsatisfactory result or a report that is difficult to understand? Here is what we explain before testing and how we report what we find.
Will the EICR make a mess or damage my home?
An EICR is an inspection and testing service, not a rewiring job. We need safe access to the consumer unit and a representative selection of sockets, switches and fixed equipment, but we work carefully and do not chase walls or redecorate as part of the inspection. We explain any access limitation rather than causing avoidable damage.
Will the power be off, and how long will the inspection take?
Some circuits need to be switched off while they are tested, so there will be periods without power. The time depends on the property, circuit count, access and any faults found. We agree access before starting and work methodically so you know what to expect rather than promising the same duration for every installation.
What happens if the EICR finds a problem?
The report records the evidence found and uses the appropriate observation codes. An unsatisfactory result does not mean we carry out repairs without your approval: we explain which items require urgent attention, which improvements are recommended and any further investigation needed, then quote remedial work separately.
Will the report clearly explain what I need to do next?
Yes. You receive the inspection details, test results, recorded limitations and coded observations in one EICR. We explain the result in plain language, identify the relevant circuit or location wherever possible and separate required remedial work from recommendations, so you can make an informed decision.
EICR Testing in Bounds Green N11 & N22
Bounds Green properties do not all present the same electrical layout. The survey separates Edwardian & Pre-War Terraces from 1930s Semis & Interwar Housing before the work is specified.
That distinction guides access, circuit testing and the written electrical installation condition report scope without relying on unsupported assumptions about the address.
What Our Customers Say About Us
Real reviews from homeowners across Bounds Green. Live Google reviews below — for all 388+ reviews across Google, Checkatrade and MyBuilder, see our testimonials page →
Book Your EICR Inspection in Bounds Green
Tell us about your Bounds Green property and we'll respond during working hours with the confirmed inspection price and next available dates.
Fully Qualified
EICRs are carried out by a qualified electrician in accordance with the current requirements for inspection and reporting, with a detailed report for the person who commissioned it.
Clear EICR Report
Your EICR report is supplied in the format and timescale confirmed when you book.
All Property Types
Houses, flats, HMOs, rental properties, commercial premises — we test all property types across North London.
From £180
Fixed prices agreed before we start. From £180 for a standard domestic EICR — no surprises.
How We Complete Your EICR Inspection
Professional EICR testing Bounds Green from start to finish. Most inspections are completed in 2–4 hours depending on property size, with reports supplied within the timescale confirmed when booking.
Initial Assessment
We review your property details, identify the consumer unit type, count circuits, and discuss any known issues requiring urgent attention or concerns you have with the electrical installation.
Visual Inspection
Complete visual examination of all accessible wiring, switches, sockets, consumer unit upgrade condition, earthing and bonding arrangements, and identification of any visible damage or deterioration.
Dead Testing
With circuits isolated, we test continuity of protective conductors, ring final circuit continuity, insulation resistance, and polarity. These tests verify the installation’s basic integrity.
Live Testing
With power restored, we measure earth fault loop impedance, RCD trip times, and verify correct operation of all protective devices. This confirms the installation will disconnect safely under fault conditions.
Assessment & Classification
We classify any observations as C1 (danger - immediate action), C2 (potentially dangerous), C3 (improvement recommended), or FI (further investigation). We’ll explain findings on-site before leaving.
Your Report
Your detailed EICR report is supplied within the timescale confirmed when you book. Includes all test results, observations, photos, recommendations, and official report for rental and safety documentation.
EICR Testing Pricing Across Bounds Green
Fixed prices with no hidden costs. You'll always receive a fixed price before testing starts.
- ✓ Full visual inspection
- ✓ Dead and live testing
- ✓ Consumer unit inspection
- ✓ Detailed report included
- ✓ Report included
- ★ Full visual inspection
- ★ Dead and live testing
- ★ Consumer unit inspection
- ★ Detailed report included
- ★ Report included
- ★ Priority scheduling
- ✓ Full visual inspection
- ✓ Dead and live testing
- ✓ Consumer unit inspection
- ✓ Detailed report included
- ✓ Report included
- ✓ Same-day quote
EICR Testing Planning for Bounds Green Property Types
Four property situations that change access, testing and the practical scope in Bounds Green.
Swipe to explore all property types
Edwardian & Pre-War Terraces
📍 Bounds Green Road, Brownlow Road, Pellatt Grove, Maidstone Road
How is EICR access planned for divided terraces & shared houses in Edwardian & Pre-War Terraces? Pre-war terraces here have frequently been altered in stages, so earlier circuits and later additions are distinguished rather than treated as one installation.
For Edwardian & Pre-War Terraces, access planning considers divided terraces & shared houses. The inspection boundary distinguishes the individual property from communal, landlord-controlled and separately metered equipment before testing begins. The written scope follows the checked layout around Bounds Green Road.
1930s Semis & Interwar Housing
📍 Bounds Green Road N11, Warwick Road, Baxter Road, Truro Road N22
What inspection and testing is relevant to 1930s Semis & Interwar Housing when considering cross-borough N11/N22 homes? The tests must follow the protective measures, earthing, bonding and circuit condition actually present. The property type gives context but cannot replace measured evidence.
In 1930s Semis & Interwar Housing, inspection and test coverage is selected with cross-borough N11/N22 homes in mind. Protective measures, earthing, bonding, circuit condition and accessories are assessed and supported by the required electrical tests. The written scope follows the checked layout around Bounds Green Road N11.
Post-War Flats & Conversion Properties
📍 Bounds Green N11, Wood Green borders N22, Brownlow Road, Commerce Road
How are access limitations handled for Post-War Flats & Conversion Properties when the inspection includes conversion flats & maisonettes? Unavailable keys, occupied rooms, restricted shutdowns or equipment that cannot be disconnected may limit testing. Every limitation and its reason must be visible in the report.
For Post-War Flats & Conversion Properties, access arrangements for conversion flats & maisonettes are agreed before testing. Access contacts and isolation authority are agreed for occupied and common areas, with exclusions written into the report rather than assumed. The written scope follows the checked layout around Bounds Green N11.
Extended Properties & HMOs
📍 Throughout Bounds Green N11 and N22 — HMO conversions, extensions
How are observations involving rear-room offices & outbuildings recorded for Extended Properties & HMOs? Part of the area falls in a restricted conversion area where many houses are already divided, so shared intakes, landlord-controlled equipment and separately occupied parts are mapped before the schedule is agreed.
In Extended Properties & HMOs, observations connected with rear-room offices & outbuildings are recorded against the evidence found. The report separates defects from recommendations and flags further investigation where the condition of an added circuit cannot yet be established. The written scope follows the checked layout around Throughout Bounds Green N11 and N22.
Need an EICR in Bounds Green?
EICR Testing Questions for Bounds Green
Property-specific questions for Bounds Green, followed by practical answers about electrical installation condition report.
What exactly is an EICR, and what does it cover?
An EICR (Electrical Installation Condition Report) is a thorough check of every electrical circuit, socket, switch, and the consumer unit in a property — to confirm the wiring is safe and meets current British Standard (BS 7671). It's a multi-page document with test data and photos, not just a quick visual check.
What we test:
- Consumer unit, earthing, and main bonding
- Every circuit (lighting, sockets, dedicated)
- RCD protection and trip times
- Insulation resistance and earth-loop impedance on every circuit
- A sample of accessories (sockets, switches, light fittings)
- Cable conditions where accessible
What an EICR does not cover: appliances (those need PAT testing) and smoke/heat alarms (separate test, but we can do both at the same visit).
What does an EICR cost in Bounds Green? Why are quotes so different?
Our Bounds Green pricing:
- Standard EICR (most 1-3 bed flats and houses): £180
- Landlord pack / 4+ bed or HMO (full report, fast turnaround, council-ready): £230
Why other quotes vary so wildly: a proper EICR takes 3-4 hours on a 3-bed property. Anyone offering £49 or £75 EICRs is doing a cursory visual check — they don't open sockets, don't measure insulation resistance on every circuit, don't pressure-test the earth. The report they hand you may say "satisfactory" while real C2 failures hide. Worse, it's worthless if Haringey Council asks for the test data — there isn't any.
What's included in our price: full inspection, written report with every observation coded, all measured test data, photos where helpful, and Clear EICR Report turnaround.
How long does an EICR take, and what happens during the inspection?
For a typical 3-bed Bounds Green property, allow 3-4 hours. Smaller flats are 2-2.5 hours; HMOs and 4+ bed properties take 4-5+ hours.
What happens during the visit:
- We'll need access to every room with electrics
- Each circuit is dead-tested (power off briefly per circuit, 5-15 minutes each)
- Sockets and switches are sampled and opened to check terminations
- The consumer unit is opened and inspected
- We test earthing, main bonding, and RCD operation
- We may need to access the loft and the meter cupboard
Power isolation: only OFF for short stretches per circuit while testing. The fridge stays on, the Wi-Fi router stays up. We give you a heads-up before each isolation so nothing important gets affected.
What you need to do: nothing special. Clear access to the consumer unit, leave us a key, and we'll lock up after.
Do I legally need an EICR? (Landlord, homeowner, buyer, or seller)
The legal requirement only bites on rented property. Quick segment guide:
- Landlord (private rented): Legally required at least every 5 years, or sooner if the previous report specifies. A valid existing report can usually be passed to a new tenant without a fresh inspection. Enforced by your local authority (Haringey Council is active on this in Bounds Green, especially in N11 and N22 HMOs).
- Owner-occupier (you live there): Not legally required. Recommended every 10 years or after any major electrical change.
- Buyer (pre-purchase): Not required by law, but increasingly requested by mortgage lenders and solicitors. Strong negotiation tool if it fails.
- Seller: Not legally required, but solicitors and buyer surveys increasingly ask for one. A clean EICR speeds up sales.
Bounds Green has a particularly high concentration of HMOs and landlord-let stock — Haringey Council has been active with EICR enforcement, with civil penalties issued for non-compliance.
My EICR came back "unsatisfactory" — what do C1, C2, C3, and FI codes mean?
Don't panic — "unsatisfactory" is a technical word, not a fire alarm. It means at least one C1, C2, or FI code was found, but those letters mean very different things:
- C1 — Danger present: Real, immediate danger (exposed live conductors, missing earth on a gas-bonded pipe). We isolate the circuit on the spot. Rare in modern wiring, more common in pre-1960s installations.
- C2 — Potentially dangerous: Could become dangerous (missing RCD on a bathroom circuit, accessible bare cable in a loft, undersized earth). Must be fixed within 28 days for landlords. Most common reason an EICR fails in Bounds Green.
- C3 — Improvement recommended: Doesn't meet current regs but isn't dangerous (e.g., plastic consumer unit where modern is metal). C3 alone does NOT fail an EICR.
- FI — Further investigation: Inspector spotted something they couldn't fully test on the day. Needs a follow-up visit, not a fail.
A report with only C3 and no other codes is satisfactory. Many "failed" EICRs are just one C2 — usually a missing RCD that's a £180-£300 fix, not a rewire.
What's the 28-day rule? What does a landlord do after a failed EICR?
The clock starts the day you receive the unsatisfactory report.
In order:
- Within 28 days — complete all C1, C2, and FI remedial work (or sooner if the report specifies — sometimes 7 or 14 days for genuine hazards)
- Within 28 days of the work completing — get written confirmation from a qualified electrician that the remedial work is done (we issue this as part of the remedial visit)
- Within 28 days of the work completing — provide that confirmation + the original EICR + the remedial certificate to your tenant
- On request — provide the same documents to your local authority
What happens if you don't comply: civil penalties up to £30,000, possible HMO licence consequences, and the council can arrange the work themselves and recover costs from you. Haringey Council does enforce — Bounds Green landlords (particularly N11 and N22 HMO operators) have been hit. Don't ignore the report.
My EICR failed — does that mean I need a full rewire?
Almost never. In our experience across Bounds Green properties, around 90% of failed EICRs are fixed with targeted remedial work, not a rewire. The most common fixes:
- No RCD protection on circuits → consumer unit upgrade (£800-£1,200, often fixes the whole report)
- Missing main bonding to incoming gas/water → 1-day remedial job (£200-£400)
- Damaged sockets or switches → replace just the damaged accessories (£20-£50 per item)
- Borrowed neutrals in lighting circuits → targeted lighting circuit rewire (£300-£600)
- Burned or damaged cable section → replace that section only (£200-£500)
A full rewire is only justified when:
- Most circuits are running pre-1970s rubber or cloth-covered cables (common on Bounds Green Road and Pellatt Grove period properties)
- The report flags multiple C1/C2 codes across the majority of circuits
Send us the failed report and we'll give you a straight read: targeted remedial, partial rewire, or full rewire — and the actual price for each option.
I'm buying a house in Bounds Green — should I get an EICR before exchange?
Yes, almost always. An EICR before exchange (£180) is one of the cheapest insurance policies in the buying process.
Why it's worth it:
- Mortgage lender comfort — some lenders ask, others appreciate a clean report
- Solicitor sign-off — buyer's solicitor's electrical-related comments get resolved without back-and-forth
- Real evidence to negotiate — if the report shows C1 or C2 codes, you can drop your offer by the cost of remedial work (typically £1,500-£8,000)
- Peace of mind — avoids buying into hidden electrical problems
Best practice: book the EICR after the homebuyer's survey comes back, before exchange. Booking-to-report turnaround is usually 2-3 days. We'll send the EICR directly to you (and your solicitor if you want).
Trap to avoid: don't accept a "vendor's EICR" that's more than 12 months old, or one done by an electrician you can't verify. Pay the £180, get your own.
I'm selling my Bounds Green home — do I need an EICR? Will it help my sale?
Not legally required, but increasingly worth the £180-£230.
Why sellers are getting one before listing:
- Solicitors are asking — slows or even kills sales when there isn't one
- Buyer surveys routinely ask "is there a current electrical certificate?" — having one removes that objection upfront
- Lenders are starting to ask
- You catch problems early — if it comes back unsatisfactory, you've got time to fix it (or price it in) before a buyer's solicitor finds it for you
When you don't need to bother: if you've just done a full rewire (the EIC from the install covers it), or you're selling at auction.
If your Bounds Green home is 10+ years from its last electrical work, an EICR before listing is usually the smarter move. We can usually fit a survey within a few days.
How often do I need an EICR?
Depends on who you are and the property:
- Landlord (rental property): Every 5 years, or sooner if the previous report specifies. A valid existing report can usually be passed to a new tenant without a fresh inspection. (UK Electrical Safety Standards 2020.)
- HMO landlord: Same 5-year rule, but Haringey Council may ask annually as part of HMO licensing — check your specific licence.
- Owner-occupier (you live there): Every 10 years recommended, or sooner after any major electrical work.
- After major works: After an extension, kitchen rewire, or any significant electrical change — even if you got an EIC for the new work, an EICR confirms the rest of the system is still safe.
- Commercial property: Every 5 years, or 1-3 years for high-risk environments.
If you're not sure when the last EICR was, check your house papers. We can also check the consumer unit for an EIC sticker dated by the last electrician.
Should I get an EICR after a kitchen extension, DIY electrical work, or any wiring changes?
Yes — and it's smarter than skipping it.
Common scenarios where an EICR catches things:
- After an extension or kitchen renovation: The new circuits get an EIC (Electrical Installation Certificate), but that only covers what was newly installed. An EICR confirms the rest of the house wasn't disturbed or compromised by the building work.
- After DIY electrical work: Anything beyond a like-for-like switch swap is technically Part P notifiable. If you (or a previous owner) added sockets, wired in a hob, or rewired a room without certification, an EICR finds what's safe and what isn't.
- Before letting (if you've previously been an owner-occupier): Required before the first tenancy — and you want to know what's there before tenants move in.
- Before insurance claims: Some insurers want a current EICR before paying out on electrical-fire claims.
Common discoveries we make on these inspections in Bounds Green: borrowed neutrals from DIY, undersized cables on extension circuits, unbonded gas pipes after kitchen replacements. Cheap to fix when caught early; expensive once they cause a fault.
What does the EICR report actually show, and what do I send to tenants, buyers, or my lender?
The EICR pack we send is a full PDF containing:
- The report front page — your details, the property, electrician qualification, "satisfactory" or "unsatisfactory" verdict
- All observations coded C1, C2, C3, or FI — with the location and reason
- Test data — insulation resistance, earth-loop impedance, RCD trip times, on every circuit
- Photos where they help explain a finding (damaged cable, missing RCD, etc.)
- Recommendations — what's needed to bring an unsatisfactory report up to satisfactory
What you forward to whom:
- Tenants — full EICR within 28 days (plus any subsequent remedial certificates)
- Local authority (Haringey Council) — same documents on request
- Buyer's solicitor — full EICR if requested during conveyancing
- Mortgage lender — some ask for a current EICR before completion
We keep originals on file indefinitely. If you lose your copy, we re-issue free.
Need an EICR in Bounds Green?
Fast, compliant testing across Bounds Green N11, N22. Appointment availability and the report delivery timescale are confirmed when you book.
